Description
At ProfHolod you can buy sandwich panels with minor damage that occurs to panels in production, when lines are started and stopped, when switching to other thicknesses and metals, and during transportation. You can also buy sandwich panels with RAL "Shtrikh" metal: these are remnants and offcuts of high-quality metal from Russian producers.
Sandwich panels with minor damage do not lose their thermal insulation properties and let you save on construction if the appearance of the building is not so important to you or if you plan to cover the sandwich panels with other materials or equipment inside the building. Discounted panels and offcuts should not be confused with sandwich panel waste: the sale offers materials that can be used in suitable construction and technical tasks.
Production lead time
The sandwich panels with minor damage are ready and are in our warehouse in Shchelkovo, Moscow region. You can pay for and pick them up on the same day or order delivery to your construction site anywhere in the world. For delivery in Moscow and the Moscow region, we arrange transportation within one day of the order being ready.
For delivery to other regions, we arrange transportation within two days of the order being ready. Need the sandwich panels delivered to another country? We arrange transportation within 3-4 days of the order being ready.
- Features of sandwich panels with minor damage
- Technical specifications
- Design
The sandwich panels are brand new, not used, and the minor defects do not affect thermal conductivity and are not obvious. The density of the mineral wool used in the discounted sandwich panels is the same as in regular ones, equal to or exceeding 95 kg/m3, providing a level of insulation suitable for professional construction. RAL "Shtrikh" metal consists of remnants and offcuts of high-quality metal from Russian producers; there may be scratches and creases on the metal surface.
Minor damage:
- scratches, unpainted spots and other damage to the paint coating
- dents
- splices of two metal coils
- profile transitions
Please note that sandwich panel sizes, color and other characteristics can be chosen only from what is in stock.
| Parameter | Value | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Insulation type | PIR Premier | |||||||||||
| Density | (40 ± 2) kg/m3 | |||||||||||
| Panel thickness, mm | 40 | 50 | 60 | 80 | 100 | 120 | 140 | 150 | 160 | 180 | 200 | |
| Weight, kg/m2 | 8,5-9,5 | 8,9-9,9 | 9,7-10,7 | 10,4-11,6 | 11,2-12,4 | 11,9-13,2 | 12,7-14,1 | 13,1-14,5 | 13,5-14,9 | 14,2-15,8 | 15-16,6 | |
| Maximum length | 16,000 mm | |||||||||||
| Width | 1,200 mm | |||||||||||
| Working width | 1,185 mm | |||||||||||
| Metal thickness | ≥ 0.45 mm | |||||||||||
| Metal surface | profiled / smooth | |||||||||||
| Standard version | RAL 9003/Zn (unpainted galvanized sheet) | |||||||||||
| Thermal conductivity coefficient | 0.022 W/mK | |||||||||||
| Thermal resistance coefficient | 1,90 | 2,38 | 2,86 | 3,81 | 4,76 | 5,71 | 6,67 | 7,14 | 7,62 | 8,57 | 9,52 | |
| Moisture absorption in 24 hours at 96% relative air humidity | 12,5% | |||||||||||
| Water absorption in 24 hours with full immersion, % by volume | 2,5% | |||||||||||
| Sound insulation | 25 dB | |||||||||||
| Indicator | Product | 40 mm | 60 mm | 80-120 mm | 150-200 mm |
|---|---|---|---|---|---|
| Fire resistance rating | Wall PUR panels | EI 15 | |||
| Wall PIR panels | EI 15 | EI 30 | EI 45 | ||
| Roof PIR panels | RE 15 | RE 15 | RE 30 | RE 30 | |
| Combustibility group | Wall PIR panels | G2 | |||
| Flammability group | B1 | ||||
| Smoke-generating ability | D3 | ||||
| Combustion products toxicity group | T2 | ||||
| Surface flame spread group | RP1 | ||||
| Panel thickness, mm | Permissible load (net), kgf/m2 | Loading diagram (permissible deflection L/200) | ||||
|---|---|---|---|---|---|---|
| Panel length, m | ||||||
| 2 | 3 | 4 | 5 | 6 | ||
| 40 | 141 | 82 | 52 | 33 | 21 |
|
| 50 | 183 | 109 | 71 | 48 | 33 | |
| 60 | 224 | 136 | 91 | 63 | 44 | |
| 80 | 307 | 191 | 131 | 94 | 69 | |
| 100 | 390 | 246 | 171 | 125 | 94 | |
| 120 | 473 | 301 | 212 | 157 | 120 | |
| 150 | 598 | 383 | 273 | 206 | 160 | |
| 180 | 723 | 466 | 335 | 254 | 199 | |
| 200 | 806 | 521 | 376 | 287 | 226 | |
| Panel thickness, mm | Permissible load (net), kgf/m2 | Loading diagram (permissible deflection L/200) | ||||
|---|---|---|---|---|---|---|
| Panel length, m | ||||||
| 2 | 3 | 4 | 5 | 6 | ||
| 40 | 106 | 47 | 21 | 8 | 2 |
|
| 50 | 144 | 68 | 34 | 16 | 7 | |
| 60 | 183 | 91 | 48 | 26 | 13 | |
| 80 | 263 | 139 | 79 | 46 | 27 | |
| 100 | 344 | 189 | 113 | 69 | 43 | |
| 120 | 426 | 241 | 148 | 94 | 61 | |
| 150 | 549 | 320 | 202 | 133 | 90 | |
| 180 | 673 | 399 | 259 | 175 | 121 | |
| 200 | 755 | 453 | 297 | 204 | 143 | |
| Panel thickness, mm | Permissible load (net), kgf/m2 | Loading diagram (permissible deflection L/200) | ||||
|---|---|---|---|---|---|---|
| Panel length, m | ||||||
| 2 | 3 | 4 | 5 | 6 | ||
| 40 | 167 | 146 | 123 | 100 | 78 |
|
| 50 | 216 | 194 | 170 | 145 | 119 | |
| 60 | 265 | 242 | 215 | 186 | 158 | |
| 80 | 363 | 339 | 309 | 278 | 245 | |
| 100 | 462 | 436 | 405 | 371 | 335 | |
| 120 | 560 | 534 | 502 | 466 | 427 | |
| 150 | 708 | 680 | 647 | 608 | 567 | |
| 180 | 856 | 827 | 792 | 752 | 708 | |
| 200 | 954 | 925 | 890 | 848 | 803 | |
| Panel thickness, mm | Permissible load (net), kgf/m2 | Loading diagram (permissible deflection L/200) | ||||
|---|---|---|---|---|---|---|
| Panel length, m | ||||||
| 2 | 3 | 4 | 5 | 6 | ||
| 40 | 133 | 91 | 56 | 29 | 7 |
|
| 50 | 180 | 132 | 91 | 56 | 29 | |
| 60 | 227 | 175 | 127 | 86 | 53 | |
| 80 | 323 | 264 | 206 | 154 | 110 | |
| 100 | 420 | 356 | 289 | 228 | 174 | |
| 120 | 517 | 449 | 376 | 306 | 243 | |
| 150 | 663 | 591 | 511 | 430 | 355 | |
| 180 | 810 | 735 | 648 | 559 | 474 | |
| 200 | 908 | 831 | 741 | 647 | 555 | |
| Panel thickness, mm | Deflection at the center, mm | Panel weight, kg | |
|---|---|---|---|
| Panel span length 6 m | |||
| Ends fixed | Ends free | ||
| 60 | 5,8 | 13,6 | 75,7 |
| 80 | 4,3 | 8,9 | 81,3 |
| 100 | 3,4 | 6,6 | 87 |
| 120 | 2,9 | 5,3 | 92,7 |
| 140 | 2,6 | 4,4 | 98,4 |
| 150 | 2,4 | 4 | 101,3 |
| 160 | 2,3 | 3,8 | 104,1 |
| 180 | 2,1 | 3,4 | 109,8 |
| 200 | 2 | 3 | 115,5 |
Wall sandwich panels with PIR Premier polyisocyanurate insulation are a modern waterproofing and thermal insulation building material.
The joint depth of PIR wall sandwich panels in the foam is 20 mm. The ProfHolod lock is the deepest among Russian analogues of PIR sandwich panels, has the longest joint length and ensures minimum heat loss at the joint
Joint gaps of PIR sandwich panels of no more than 0.5 mm reduce heat loss and the use of installation materials. The external joint gap ensures the stability of the structure under thermal expansion.
The edges of the metal sheets go into the foam, giving the sandwich panels additional rigidity. When PIR sandwich panels are joined along the metal sheet, a triangular groove is formed that holds the sealant. The conical shape of the metal facing of the lock guides the panels when they are joined.
The 1.5 mm deep micro-profile gives the sandwich panels maximum rigidity.
Dimensions of three-layer wall sandwich panels with PIR Premier:
- Thickness of wall sandwich panels: 40—200 mm
- Width of wall sandwich panels: 1190, 1000 mm
- Length of wall sandwich panels: up to 16,000 mm
PIR wall sandwich panels are produced with a PE foam sealing tape. When installing low-temperature chambers, to eliminate cold bridges it is recommended to remove the PE foam tape and fill the joint with mounting foam. The tape should be kept for an effective joint between sandwich panels in medium-temperature chambers.
PIR Premier sandwich panels have the European CE certificate and show resistance of more than 185 kPa in compressive strength tests at 10% deformation and more than 160 kPa in tensile tests at a density of 40 kg/m3.
At ProfHolod you can order PIR wall sandwich panels to your technical specification, of any required length, with any metal of Russian or foreign production, for any type of facility: warehouses, poultry houses, cowsheds, food production facilities, workshops and so on.
You can also order the thickness you need or consult our engineers: the thickness of wall sandwich panels is selected taking into account the climate and each specific facility.
Surface
profiling


Services
Have a question about our products?
Write your question – a personal manager will suggest
exactly what you need and provide photos
of similar projects in your region.