Description
More and more cottages and country houses are being built from sandwich panels. Customers are attracted by the speed of construction, the energy efficiency of the house, the possibility of building in any climate, the chance to create a unique design, including with wood-grain metal, and the absence of any need for exterior finishing. Private housing construction mainly uses the most modern sandwich panels with PIR Premier insulation. They hold temperature better than mineral wool sandwich panels, with a thermal conductivity of 0.0194 versus 0.041 W/m*K, and are much lighter.
Building a sports complex from mineral wool sandwich panels is a cost-effective solution when you need a reliable, durable building quickly and at an optimal price. A fast-build sports complex made of sandwich panels meets fire safety requirements, since panels with mineral wool insulation do not burn. A sports complex can be built on any construction site without an expensive, heavy foundation, which significantly shortens installation time and reduces its cost. The cost of construction materials is calculated individually: contact your personal manager at our company. We will select exactly what your project requires.
We will help you design a solution that suits you
We manufacture and help find contractors
in Russia and 27 countries worldwide
Advantages
-
Speed
Your sandwich panels will be ready within 2 weeks of the order being placed -
Free consultations
ProfHolod technical specialists will advise you free of charge on all matters related to building sports complexes, before, during and after the project -
Any color or combination of colors
outside and insideFor your project you can order any metal from leading Russian producers in any RAL color and with various coating options -
Quality
ProfHolod products are used in 27 countries around the world, PIR Premier sandwich panels carry the CE mark and are produced in accordance with the European certificate EN 14509. ProfHolod produces more than 3 million sq. m of sandwich panels a year: every third polyurethane panel and every tenth sandwich panel with any insulation produced in Russia is made at ProfHolod
Production lead time
Two continuous production lines for sandwich panels with PIR Premier polyisocyanurate foam and mineral wool cores, with a capacity of up to 6,000,000 square meters per year, make it possible to forecast delivery times for products for building cottages or sports complexes as accurately as possible.
Your sandwich panels will be ready within 2 weeks of the order being placed. For delivery in Moscow and the Moscow region, we arrange transportation within one day of the order being ready.
For delivery to other regions, we arrange transportation within two days of the order being ready. Need to deliver products to another country? We will arrange transportation within 3-4 days of the order being ready.
- Documentation
- Technical specifications
- Sandwich panel insulation
- Design
| Parameter | Value | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Insulation type | PIR Premier | |||||||||||
| Density | (40 ± 2) kg/m3 | |||||||||||
| Panel thickness, mm | 40 | 50 | 60 | 80 | 100 | 120 | 140 | 150 | 160 | 180 | 200 | |
| Weight, kg/m2 | 8,5-9,5 | 8,9-9,9 | 9,7-10,7 | 10,4-11,6 | 11,2-12,4 | 11,9-13,2 | 12,7-14,1 | 13,1-14,5 | 13,5-14,9 | 14,2-15,8 | 15-16,6 | |
| Maximum length | 16,000 mm | |||||||||||
| Width | 1,200 mm | |||||||||||
| Working width | 1,185 mm | |||||||||||
| Metal thickness | ≥ 0.45 mm | |||||||||||
| Metal surface | profiled / smooth | |||||||||||
| Standard version | RAL 9003/Zn (unpainted galvanized sheet) | |||||||||||
| Thermal conductivity coefficient | 0.022 W/mK | |||||||||||
| Thermal resistance coefficient | 1,90 | 2,38 | 2,86 | 3,81 | 4,76 | 5,71 | 6,67 | 7,14 | 7,62 | 8,57 | 9,52 | |
| Moisture absorption in 24 hours at 96% relative air humidity | 12,5% | |||||||||||
| Water absorption in 24 hours with full immersion, % by volume | 2,5% | |||||||||||
| Sound insulation | 25 dB | |||||||||||
| Indicator | Product | 40 mm | 60 mm | 80-120 mm | 150-200 mm |
|---|---|---|---|---|---|
| Fire resistance rating | Wall PUR panels | EI 15 | |||
| Wall PIR panels | EI 15 | EI 30 | EI 45 | ||
| Roof PIR panels | RE 15 | RE 15 | RE 30 | RE 30 | |
| Combustibility group | Wall PIR panels | G2 | |||
| Flammability group | B1 | ||||
| Smoke-generating ability | D3 | ||||
| Combustion products toxicity group | T2 | ||||
| Surface flame spread group | RP1 | ||||
| Panel thickness, mm | Permissible load (net), kgf/m2 | Loading diagram (permissible deflection L/200) | ||||
|---|---|---|---|---|---|---|
| Panel length, m | ||||||
| 2 | 3 | 4 | 5 | 6 | ||
| 40 | 141 | 82 | 52 | 33 | 21 |
|
| 50 | 183 | 109 | 71 | 48 | 33 | |
| 60 | 224 | 136 | 91 | 63 | 44 | |
| 80 | 307 | 191 | 131 | 94 | 69 | |
| 100 | 390 | 246 | 171 | 125 | 94 | |
| 120 | 473 | 301 | 212 | 157 | 120 | |
| 150 | 598 | 383 | 273 | 206 | 160 | |
| 180 | 723 | 466 | 335 | 254 | 199 | |
| 200 | 806 | 521 | 376 | 287 | 226 | |
| Panel thickness, mm | Permissible load (net), kgf/m2 | Loading diagram (permissible deflection L/200) | ||||
|---|---|---|---|---|---|---|
| Panel length, m | ||||||
| 2 | 3 | 4 | 5 | 6 | ||
| 40 | 106 | 47 | 21 | 8 | 2 |
|
| 50 | 144 | 68 | 34 | 16 | 7 | |
| 60 | 183 | 91 | 48 | 26 | 13 | |
| 80 | 263 | 139 | 79 | 46 | 27 | |
| 100 | 344 | 189 | 113 | 69 | 43 | |
| 120 | 426 | 241 | 148 | 94 | 61 | |
| 150 | 549 | 320 | 202 | 133 | 90 | |
| 180 | 673 | 399 | 259 | 175 | 121 | |
| 200 | 755 | 453 | 297 | 204 | 143 | |
| Panel thickness, mm | Permissible load (net), kgf/m2 | Loading diagram (permissible deflection L/200) | ||||
|---|---|---|---|---|---|---|
| Panel length, m | ||||||
| 2 | 3 | 4 | 5 | 6 | ||
| 40 | 167 | 146 | 123 | 100 | 78 |
|
| 50 | 216 | 194 | 170 | 145 | 119 | |
| 60 | 265 | 242 | 215 | 186 | 158 | |
| 80 | 363 | 339 | 309 | 278 | 245 | |
| 100 | 462 | 436 | 405 | 371 | 335 | |
| 120 | 560 | 534 | 502 | 466 | 427 | |
| 150 | 708 | 680 | 647 | 608 | 567 | |
| 180 | 856 | 827 | 792 | 752 | 708 | |
| 200 | 954 | 925 | 890 | 848 | 803 | |
| Panel thickness, mm | Permissible load (net), kgf/m2 | Loading diagram (permissible deflection L/200) | ||||
|---|---|---|---|---|---|---|
| Panel length, m | ||||||
| 2 | 3 | 4 | 5 | 6 | ||
| 40 | 133 | 91 | 56 | 29 | 7 |
|
| 50 | 180 | 132 | 91 | 56 | 29 | |
| 60 | 227 | 175 | 127 | 86 | 53 | |
| 80 | 323 | 264 | 206 | 154 | 110 | |
| 100 | 420 | 356 | 289 | 228 | 174 | |
| 120 | 517 | 449 | 376 | 306 | 243 | |
| 150 | 663 | 591 | 511 | 430 | 355 | |
| 180 | 810 | 735 | 648 | 559 | 474 | |
| 200 | 908 | 831 | 741 | 647 | 555 | |
| Panel thickness, mm | Deflection at the center, mm | Panel weight, kg | |
|---|---|---|---|
| Panel span length 6 m | |||
| Ends fixed | Ends free | ||
| 60 | 5,8 | 13,6 | 75,7 |
| 80 | 4,3 | 8,9 | 81,3 |
| 100 | 3,4 | 6,6 | 87 |
| 120 | 2,9 | 5,3 | 92,7 |
| 140 | 2,6 | 4,4 | 98,4 |
| 150 | 2,4 | 4 | 101,3 |
| 160 | 2,3 | 3,8 | 104,1 |
| 180 | 2,1 | 3,4 | 109,8 |
| 200 | 2 | 3 | 115,5 |
| Panel thickness, mm | Panel weight with a metal facing thickness of 0.5 mm and an insulation density of 105 kg/m³ | |||
|---|---|---|---|---|
| Roof panel, 1000 mm wide | Wall panel, 1000 mm wide | Wall panel, 1180 mm wide | ||
| kg/m²; = kg/linear m | kg/m²; = kg/linear m | kg/m² | kg/linear m | |
| 50 | 15,032 | 15,063 | 13,566 | 16,008 |
| 60 | 16,082 | 16,113 | 14,616 | 17,247 |
| 80 | 18,182 | 18,213 | 16,717 | 19,735 |
| 100 | 20,282 | 20,313 | 18,816 | 22,203 |
| 120 | 22,382 | 22,413 | 20,916 | 24,681 |
| 150 | 25,532 | 25,563 | 24,066 | 28,398 |
| 170 | 27,632 | 27,663 | 26,166 | 30,876 |
| 200 | 30,782 | 30,813 | 29,316 | 34,593 |
| Panel type | Panel thickness, mm | Reduced heat transfer resistance R0, m²·ºC/W |
|---|---|---|
| PST Z PST SF | 50 | 1,378 |
| 80 | 2,110 | |
| 100 | 2,598 | |
| 120 | 3,085 | |
| 150 | 3,817 | |
| 170 | 4,305 | |
| 200 | 5,037 |
| Panel thickness, mm | Span, m | Support width, mm | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 3,0 | 3,5 | 4,0 | 4,5 | 5,0 | 5,5 | 6,0 | 6,5 | 9,0 | ||
| 50 | 151 | 129 | 89 | 60 | 40 | 27 | 17 | - | - | 40 |
| 80 | 163 | 139 | 122 | 107 | 87 | 68 | 50 | 37 | - | 40 |
| 100 | 174 | 149 | 131 | 116 | 105 | 90 | 75 | 64 | 20 | 40 |
| 120 | 203 | 149 | 153 | 136 | 122 | 108 | 90 | 77 | 37 | 50 |
| 150 | 232 | 199 | 174 | 155 | 139 | 127 | 113 | 96 | 50 | 60 |
| 200 | 261 | 224 | 196 | 174 | 157 | 143 | 131 | 121 | 67 | 70 |
| Panel thickness, mm | Span, m | Support width, mm | ||||||
|---|---|---|---|---|---|---|---|---|
| 3,0 | 3,5 | 4,0 | 4,5 | 5,0 | 5,5 | 6,0 | ||
| 50 | 104 | 88 | 76 | 67 | 60 | 54 | 50 | 60 |
| 80 | 115 | 97 | 84 | 74 | 66 | 60 | 55 | 60 |
| 100 | 126 | 107 | 92 | 81 | 73 | 66 | 60 | 60 |
| 120 | 138 | 116 | 100 | 88 | 79 | 71 | 65 | 70 |
| 150 | 155 | 131 | 113 | 99 | 88 | 80 | 73 | 80 |
| 200 | 184 | 155 | 134 | 117 | 105 | 94 | 86 | 100 |
You can build a fast-build sports complex from PIR Premier sandwich panels if the building capacity does not exceed 600 seats, or from mineral wool sandwich panels if the building is designed for 600 seats or more. PIR Premier sandwich panels have certified high fire resistance (EI45) and combustibility group (G1, low-combustible), as well as the European CE certificate.
Dimensions of three-layer wall sandwich panels with PIR Premier:
- Thickness of wall sandwich panels: 40—200 mm
- Width of wall sandwich panels: 1190, 1000 mm
- Length of wall sandwich panels: up to 16,000 mm
- Thermal conductivity up to 0.0194 W/m*K
Mineral wool sandwich panels cannot match the thermal conductivity of PIR, but they provide higher fire protection. ProfHolod manufactures mineral wool sandwich panels in accordance with the current GOST 32603-2021 for buildings with increased fire safety requirements.
Dimensions of wall sandwich panels with mineral wool insulation:
- Thickness of wall sandwich panels: 50 — 250 mm
- Length of wall sandwich panels: 2,000 — 16,000 mm
- Thermal conductivity up to 0.041 W/m*K
Your personal manager at ProfHolod will help you choose sandwich panels with the insulation that suits your facility.
Sandwich panels let you quickly build a reliable, functional fast-build sports complex of any complexity and purpose. Because sandwich panels are lightweight, construction requires neither a heavy foundation nor heavy machinery, saving not only money but also time.
Advantages of a sports complex structure made of sandwich panels:
- Strength and stability. Sandwich panels have high mechanical strength and wear resistance. They retain their properties for a long time, even in adverse weather conditions. In addition, sandwich panels can withstand heavy loads, which makes it possible to build frames of various shapes and sizes
- Savings on transportation. Light and compact sandwich panels significantly reduce transportation costs
- Thermal insulation. Sandwich panels effectively retain heat and cold inside the building, saving energy and reducing heating and air-conditioning costs
- Sound insulation. Thanks to the fibrous structure and high density of the mineral wool insulation, the panels have excellent sound-insulating properties. This reduces noise inside the building and creates comfortable conditions for sports
- Fire safety. PIR sandwich panels have certified high fire resistance: G1 combustibility group, EI45. Mineral wool sandwich panels are used in buildings with increased fire safety requirements: they are non-combustible, safe, and have a fire resistance rating of up to EI 180
Fixing locks
40-60 mm
80-150 mm
180-200 mm
Surface
profiling



Services
Have a question about our products?
Write your question – a personal manager will suggest
exactly what you need and provide photos
of similar projects in your region.